Cooling and air-conditioning pipework
Condensation attacks from the outside. Glycol tests from within. Stainless steel resists from both sides.
TAVINOX PRESS is a stainless steel press-fit system certified for chilled water systems. Compatible with water/glycol mixtures up to 50/50.

Why stainless steel for cooling pipework
Cooling places specific demands on piping. External surface condensation causes corrosion in conventional materials.
Resistance to external condensation
Stainless steel does not corrode on the surface or at points of damaged insulation. A common problem with steel pipework in cooling applications.
Universal temperature range
One material for both heating and cooling modes. Stainless steel handles both without loss of properties, ideal for reversible heat pumps.
No corrosion inside or outside
Stainless steel resists both the medium and the surrounding environment simultaneously, unlike carbon steel which requires protection from both sides.
Inert to glycol mixtures
Stainless steel does not react with water/glycol mixtures even upon their degradation, unlike carbon steel where glycol can cause corrosion.
Long-term flow stability
The smooth internal surface, free of corrosion deposits, maintains design flow rates and pressure losses throughout the service life.
Leak-tightness
Correctly pressed joints minimise the risk of micro-leaks which, in conventional joints, cause condensation damage to building structures.
Designed for all building types
Looking for other applications of the TAVINOX PRESS stainless steel system?
Other application areasTechnical parameters for cooling pipework
| Parameter | Value |
|---|---|
| Operating pressure | 6 bar |
| Min. operating temperature | −10 °C |
| Fitting material | AISI 316L (1.4404) |
| Tube material | AISI 316L / AISI 304L |
| Size range – press-fit | 15–108 mm |
| Size range – grooved | 133–323 mm |
| Press profile | M |
| Seal | EPDM (−55 °C to +120 °C) |
| Unpressed-joint detection | Leak Detect (from 0.1 bar) + blue indicator ring |
Connection to other materials: Combination with copper and other stainless steels is unrestricted. With carbon steel only via a brass dielectric nipple (min. 50 mm), with the flow always running from carbon steel to stainless steel. The complete parameters of the TAVINOX PRESS system are given in the technical manual.
Downloads
TAVINOX PRESS Technical Manual
includes sections such as:
- Cooling systems — application overview
- Glycol mixtures — compatibility
- Protection against condensation
- Installation in cooling circuits
- Reversible heat pumps — recommendations
“Cooling systems suffer from corrosion from the outside even before from the inside. Stainless steel eliminates this in both cases.”
Choosing stainless steel piping for cooling distribution reduces the risk of condensation-related failures and extends the lifetime of the entire system.
Other application areas of the TAVINOX stainless steel system

Drinking water distribution
AISI 316L / 304L, DVGW and ITC certified. Hygienically safe, biofilm-free, no chemical water treatment required.
More information
Heating systems
16 bar / 110 °C, EN 12828. Zero oxygen diffusion, clean heating circuit, no chemical water treatment.
More information
Fire protection pipework
PAVUS certification per VdS CEA 4001. Ø22–108 mm, wet and dry systems. Classes LH, OH1–OH4.
More information
Compressed air distribution
10 bar / 60 °C, class 1–3 per ISO 8573-1. Vacuum to –0.8 bar. Zero internal corrosion, clean air without contamination.
More information
Heat pumps and solar systems
6 bar, –35 to +110 °C, short-term 200 °C. Inert to glycol mixtures, one material for both heat pump modes.
More information
Service and industrial water
Chlorides up to 600 mg/l, 16 bar / 110 °C. AISI 316L with 2–3 % Mo. Compatible with reverse osmosis, rainwater and pools.
More information