Heating systems
Heat should flow reliably. Every day, every winter.
TAVINOX PRESS is a stainless steel press-fit system suitable for building heating systems designed to EN 12828.

Why stainless steel for heating systems
A heating system must operate reliably for many years. Not only at start-up, but also after countless thermal cycles.
Zero oxygen diffusion
Stainless steel piping does not allow oxygen to permeate into the heating water. It protects radiators and pumps from corrosion, unlike other materials.
No chemical water treatment
The piping does not require corrosion inhibitors in the heating water, unlike carbon steel distribution systems where water treatment is mandatory.
Minimal thermal expansion
Simpler expansion compensation, fewer compensators, fewer problems when designing long pipe runs.
Clean heating circuit
No corrosion products are generated that would foul heat exchangers, valves and control fittings. The system remains hydraulically clean throughout its service life.
Service life without replacement
When operated within design conditions, stainless steel heating distribution serves for the full lifespan of the building without the need for full replacement.
Resistance to high flow rates
Essential for systems with variable flow and variable-speed pump drives.
Designed for all building types
Looking for other applications of the TAVINOX PRESS stainless steel system?
Other application areasTechnical parameters for heating systems
| Parameter | Value |
|---|---|
| Operating pressure (EN 12828) | 16 bar |
| Max. operating temperature | 110 °C |
| Fitting material | AISI 316L (1.4404) |
| Tube material | AISI 316L / AISI 304L |
| Size range – press-fit | 15–108 mm |
| Size range – grooved | 133–323 mm |
| Press profile | M |
| Seal – standard | EPDM (−55 °C to +120 °C) |
| Seal – high-temperature | FKM (−20 °C to +160 °C, 200 °C intermittently) |
| Thermal expansion | α = 0.0165 mm/m·K |
| Unpressed-joint detection | Leak Detect (from 0.1 bar) + blue indicator ring |
Connection to other materials: Combination with copper and other stainless steels is unrestricted. With carbon steel only via a brass dielectric nipple (min. 50 mm), with the flow always running from carbon steel to stainless steel. The complete parameters of the TAVINOX PRESS system are given in the technical manual.
Downloads
TAVINOX PRESS Technical Manual
includes sections such as:
- Sizing to EN 12828
- Thermal expansion and compensation of pipe runs
- Heating water requirements
- Installation and pressure testing
- Compatibility with boilers and heat pumps
“A heating system is designed for decades. The choice of pipe material decides whether you will be dealing with repairs in 20 years — or not.”
Stainless steel press-fit piping eliminates the risk of corrosion and circuit fouling throughout the projected lifespan of the building.
Other application areas of the TAVINOX stainless steel system

Drinking water distribution
AISI 316L / 304L, DVGW and ITC certified. Hygienically safe, biofilm-free, no chemical water treatment required.
More information
Cooling and air-conditioning pipework
6 bar / –10 °C. Resistant to external condensation, inert to water/glycol 50/50 mixtures.
More information
Fire protection pipework
PAVUS certification per VdS CEA 4001. Ø22–108 mm, wet and dry systems. Classes LH, OH1–OH4.
More information
Compressed air distribution
10 bar / 60 °C, class 1–3 per ISO 8573-1. Vacuum to –0.8 bar. Zero internal corrosion, clean air without contamination.
More information
Heat pumps and solar systems
6 bar, –35 to +110 °C, short-term 200 °C. Inert to glycol mixtures, one material for both heat pump modes.
More information
Service and industrial water
Chlorides up to 600 mg/l, 16 bar / 110 °C. AISI 316L with 2–3 % Mo. Compatible with reverse osmosis, rainwater and pools.
More information